10mm  3/8’

15mm  5/8’

20mm  3/4’

25mm  1’

40mm  1 1/2’

Recommended maximum width / length ratios

1 : 1

1 : 1.5

1 : 2

1 : 2

1 : 3

Tiles: average kilograms per square meter (kg/m2)

25

38

50

63

100

Tile: average pounds per square foot (lb/ft2)

5

7.5

10

12.5

20

Tile Tolerances

Typical

Size/Rectangularity: ± 0.75mm    Thickness: ± 0.5 – 1.5mm    Max Curvature: ± 0.5%

Installation

Flooring: Adhesive fix only using materials and procedures in Sadlerstone technical literature.

Cladding: Adhesive or mechanically fix.

Recommended Grout Joints

Flooring: 2 mm – 5 mm (1/8” – 1/4”) or minimum 0.5% of long side of tile.

Cladding: As specified for installation method/materials (min 0.5%).

Expansion Joints

As per engineer’s details or maximum intervals of 6m (20’) for interior and 4.5m (15’) for exterior applications.

Sealing

Supplied with impregnating primer seal. Apply further impregnator after initial clean. As surface
is subject to acid aggression (eg. lemon juice, vinegar), food area tiles should be fully sealed.

Colour Fastness

Negligible change in colour over 5 years.

Warranty

A limited warranty against wear is provided.

Slip and Durability Tests

Conducted by Smith-Emery Laboratories, California, USA

Test Type

Results

Static Coefficient of Friction
(ASTM C 1028-96)
Smooth tile after cleaning

Test Condition
Dry Neolite
Wet Neolite

Individual SCOF
0.85
0.88

SCOF (Neolite Correction Factor)
(0.86)
(0.85)

Static Coefficient of Friction
(ASTM C 1028-96)
Textured tile after cleaning

Test Condition
Dry Neolite
Wet Neolite

Individual SCOF
0.89
0.88

SCOF (Neolite Correction Factor)
(0.90)
(0.85)

Static Coefficient of Friction
(ASTM C 1028-96)
Terrazzo Honed tile after cleaning

Test Condition
Dry Neolite
Wet Neolite

Individual SCOF
0.91

0.65

SCOF (Neolite Correction Factor)
(0.89)
(0.62)

Static Coefficient of Friction
(ASTM C 1028-96)
Terrazzo Polished tile after cleaning

Test Condition
Dry Neolite
Wet Neolite

Individual SCOF
0.95
0.58

SCOF (Neolite Correction Factor)
(0.93)
(0.55)

Abrasion

Average Abrasive Wear Index:

178

Robinson Floor Test

HEAVY COMMERCIAL Classification as per TCA installation handbook.

Freeze/Thaw

No significant change or material erosion after 25 cycles.

Strength Tests

Australian Laboratories

Test Type

Results

Test Type (AS/NZS 4586 – 2004)

BPN*

Class

Compressive Strength (min)

60 mpa (8,702 psi)

Smooth Tile: Wet Slip

36

X

Flexural Strength

9.6 mpa (1,401 psi)

Textured Tile: Wet Slip

62

V

 

 

Terrazzo Tile: Wet Slip

59

V

*BPN = British Pendulum Number. Class refers to Australian Standard (AS/NZS 4586 - 2004) for slip resistance.
The Australian standard states that "factors such as usage, cleaning systems, applied coatings and patterns of wear
may affect the characteristics of the surface after classification."